Download FLUKE PM PM PM PM 2X2MV,MHZ OSCILLOSOPE SM service manual & repair info for electronics experts. Re: Fluke PM manual needed (MHz scope) The service manual for Fluke / Philips PM PM PM PM can be found. PM ). Deflection Manual positioning: Horizontal, Vertical, Both . Web access: com.

Author: Kegami Gujind
Country: Iraq
Language: English (Spanish)
Genre: Literature
Published (Last): 13 April 2004
Pages: 336
PDF File Size: 12.82 Mb
ePub File Size: 1.65 Mb
ISBN: 922-9-44022-198-1
Downloads: 41187
Price: Free* [*Free Regsitration Required]
Uploader: Gora

Limitation of Liability 3. Put a new one 1. However, many of the standard electronic components can be obtained from other local suppliers. Printed circuit board lay-out of external trigger unit I cleaned up after the blown fuse.

Oscilloscope Fluke PM3082 powersupply problem?

Page The oscilloscope must be capable of displaying signal amplitudes that are larger than the screen. Input Characteristics Note 1: Handle the CRT and its side connections carefully. Conduct of Sale 4. Verify that a horizontal line of 4.

Fluke PM3082 Service Manual

Really don’t know why the mains fuse went. For the avoidance of doubt removal includes where applicable disconnection from the mains electricity supply and the detachment of any lots which are fixed.

There is a certain instability in the starting point, the so called jitter, of the DTB. This gives a time-linear voltage across the capacitor; the so- called sawtooth or sweep signal. The input circuit is formed by IC D Watch the CRT and check that no errors are reported.

Impaired Safety-protection Components which are important for the safety of the instrument may only be replaced by components obtained through your local FLUKE organisation.

Default by Buyer Upon failure by the Buyer for whatsoever reason: Synchronization is achieved via SCL. CHIP C ATCAL can supply several accurate voltages that are used for vertical calibrations. There are really no sign of flames anywhere. Please also note that some lots are located on the first floor so please ensure that sufficient resources are in place for the removal of your lots. In practice, a low frequency signal with an amplitude equivalent to 24 divisions must be displayed with no distortion.

  BREVITATE VITAE SENECA PDF

Page 3 – Use terminations. The purchaser should ensure that their contractors hold sufficient public liability insurance, copies of which should be made available to Lambert Smith Hampton if demanded.

The Buyer shall, on request, satisfy the Auctioneers in relation to its removal procedures, and the removal of waste materials must be undertaken by an approved and licensed contractor. Page 34 – Description The unit A1 description is split into the following chapters: I appreciate your wise input!

Oscilloscope Fluke PM powersupply problem?

Best regards PAF Flames out the back from an incorrect measurement set up? As input signals are used the output signals at pin 7 and 3 of N Neither the Auctioneers nor the Vendor shall be liable to account to the Buyer in the event of a re-sale at a higher price than the price contracted to be paid by the Buyer. Ends from 15 Sep In no circumstances will the Auctioneers or the Vendor be kanual if any Goods or part thereof be lost, stolen, damaged or destroyed after the Majual is declared.

The value of this shift is measured here. Some of these voltages remain some time after disconnecting the instrument from the mains. Verify that the jitter of pm302 DTB is not more than 0. Use the internal termination when available.

The signal is high during field 1 and low during field 2. Pull the two self-locking white plastic clamps. Remove all superfluous soldering material. Also the vertical CRT text signal is applied to D pin 15 and He said that during a measurement, the oscilloscope’s powersupply just bang and a flame came out of the rear panel. The output signals are measured on the X-deflection plates of the CRT. Notices Any notices or other communications shall be in writing and, if sent by post, shall be deemed to have been received by the addressee on the second working day after posting or, if the addressee is outside the United Kingdom, on the fifth working day after positing.

  AAPDA PRABANDHAN PDF

Previous certification and safe history documentation will be available to view during the sale period and purchasers must make it their responsibility to request this using the codes on the equipment and sign accordingly. This diagram shows the final intensity Fouke and focusing amplifiers.

Table Of Contents 6. Manual calibration data are protected by a keyword and a seal and must be changed by qualified personnel only.

The Buyer shall ensure so far as is reasonably practicable that they comply with the Health and Safety at WorkActCOSHH and other current legislation in connection with the removal, handling and transport of such dangerous substances and or hazardous waste or shall employ a specialist contractor to remove them. Just primary shorts has the power to do this, in my opinion based on hundreds of smps repairs.

Over and under-voltage protection To protect the oscilloscope circuitry against over-voltage and the supply circuits against overload, the power supply is provided with a protection circuit. The balanced input signal for triggering on vertical channels 1,2, 3 or 4 is applied to pin 7 and 8. Before purchasing or ordering replacement parts, check the parts list for value, tolerance, rating and description.

Page – Probe Adjust signal; frequency and outpu The driver transistors are V and V